Computing Center Dry Cooler

Computing Center Dry Cooler

Liquid Immersion Cooling dry cooler using titanium plates and closed-loop design, tailored for high-performance computing, achieving PUE <1.1 and reducing water consumption by 95%.

Product Introduction

Liquid Immersion Cooling Dry Cooler for Data Centers

product-1170-878

Engineered for sustainability, this data center dry cooler reduces water consumption by eliminating evaporative cooling. The adiabatic pre-cooling system sprays fine mist onto the coils during peak temperatures, enhancing efficiency without significant water use. The EC fans, controlled by a Building Management System (BMS), optimize airflow based on ambient conditions, cutting energy costs by 35%. In cloud computing facilities, it maintains PUE (Power Usage Effectiveness) below 1.2, aligning with industry sustainability goals. The modular design allows for future expansion, while the self-cleaning coils prevent dust accumulation, reducing maintenance downtime. With a service life of 20+ years, it offers a low total cost of ownership for large-scale data centers.

 

This Liquid Immersion Cooling dry cooler, featuring titanium plates and a closed - loop design, is tailored for high - performance computing. It achieves a Power Usage Effectiveness (PUE) of < 1.1 and reduces water consumption by 95%, making it a sustainable solution for data centers.

 

Product Details

 

1

Core Design & Sustainability

◆ Water - Free Cooling: Eliminates evaporative cooling, relying on a closed - loop system with titanium plates. This design reduces water consumption by 95%, aligning with data center sustainability goals (e.g., achieving a Water Usage Effectiveness (WUE) below 1.2).
◆ Material & Durability: Titanium plates offer excellent corrosion resistance and thermal conductivity. The closed - loop design prevents external contamination, ensuring long - term reliability in data center environments.

 

2

Performance & Efficiency

◆ High - Performance Cooling: The spray - fine mist system activates during peak temperatures, enhancing heat dissipation efficiency without significant water use. This, combined with EC fans, helps maintain a PUE of < 1.1 in high - performance computing (HPC) and cloud computing facilities.

◆ Energy Savings: EC fans, controllable via a Building Management System (BMS), optimize airflow based on ambient conditions. This cuts energy costs by 33% compared to traditional cooling systems.

 

3

Application & Longevity

◆ Data Center Use: Ideal for cloud computing facilities and large - scale data centers. The modular design allows for future expansion, adapting to growing computing demands.
◆ Low Maintenance & Long Life: Self - cleaning coils prevent dust accumulation, reducing maintenance downtime. With a service life of 20+ years, it offers a low total cost of ownership for data center operators.

 

4

Key Specifications (Typical)

Parameter

Detail

Cooling Method

Liquid immersion with closed - loop titanium plates

PUE Target

< 1.1

Water Reduction

95% (vs. evaporative cooling)

Fan Type

EC fans (BMS - controllable)

Energy Cost Cut

33% (via BMS - optimized airflow)

Service Life

20+ years