Home / Products / Dry Cooler / Details
Horizontal Dry Cooler

Horizontal Dry Cooler

Server dry cooler with redundant fans and modular design, ideal for computing center retrofits, maintaining 24/7 uptime with hot-swappable components and predictive maintenance capabilities.

Product Introduction

Server Dry Cooler for Computing Center Retrofits

product-1175-882

The V-type dry cooler is engineered for high-efficiency heat dissipation in industrial settings. Its distinctive V-shaped configuration maximizes surface area while minimizing footprint, making it ideal for factories with limited space. Constructed with aluminum fins and copper tubes, it offers excellent corrosion resistance and thermal conductivity. The modular design allows for easy scalability, with units capable of handling heat loads from 50 kW to 5 MW. In chemical plants, it cools process fluids (such as glycol) by rejecting heat to ambient air, eliminating the need for water-based cooling systems. The variable-speed fans adjust to temperature fluctuations, reducing energy consumption by up to 30%. With a robust galvanized steel frame and IP55 protection, it withstands harsh environments, ensuring continuous operation in outdoor installations.

 

Tailored for computing center retrofits, this Server Dry Cooler ensures 24/7 uptime with redundant fans, hot - swappable components, and predictive maintenance. It integrates efficiency, reliability, and modularity, addressing heat dissipation challenges in data centers while aligning with sustainability goals.

 

Core Specifications

 

Parameter

Detail

Modular Design

Scalable modules (50 kW – 5 MW per unit)

Fan Type

Redundant, hot - swappable variable - speed fans

Materials

Corrosion - resistant housing; high - conductivity heat exchanger core

Energy Savings

Up to 30% via variable - speed fan control

Protection Grade

IP55 (withstands harsh outdoor environments)

 

Product Details

 

1

Structural Design & Durability

◆ Housing: Constructed from high - grade, corrosion - resistant steel, the cooler's housing ensures long - term durability in data center environments. It can withstand temperature fluctuations, dust, and minor moisture exposure, making it suitable for both indoor and outdoor installations.
◆ Modular Units: Each modular unit measures 800mm (W) × 1200mm (D) × 1500mm (H) and weighs approximately 200 kg (per 50 kW module). The compact size allows easy integration into existing computing centers, even those with limited space. Modules can be stacked or arranged in parallel, enabling seamless scalability as data center heat loads increase.

 

2

Thermal Performance

◆ Heat Exchanger Core: The core uses a combination of aluminum fins and copper tubes, maximizing thermal conductivity. It can dissipate heat loads ranging from 50 kW to 5 MW per module, maintaining stable server temperatures (18°C – 27°C optimal range) during peak loads.

◆ Redundant Fans: The cooler is equipped with dual redundant fans. Each fan has a diameter of 400mm, a maximum airflow of 5000 m³/h, and a power consumption of 150 W (at full speed). In case of a fan failure, the redundant unit activates within 0.5 seconds, preventing cooling interruptions. The variable - speed control adjusts fan speed based on temperature sensors, reducing energy use by up to 30% during low - load periods.

 

3

Maintenance & Reliability

◆ Hot - Swappable Components: Fans, sensors, and minor components support hot - swapping. This means components can be replaced without shutting down the cooling system, ensuring 24/7 data center operation. A full fan replacement takes less than 10 minutes with standard tools.
◆ Predictive Maintenance: Built - in sensors monitor fan speed, temperature differentials, and component vibrations. The system uses AI - driven algorithms to predict failures (e.g., fan bearing wear, sensor drift) up to 2 weeks in advance. Maintenance alerts are sent to the data center management system, allowing scheduling during off - peak hours (e.g., late - night or weekends).

 

4

Energy Efficiency & Sustainability

◆ Power Consumption: The cooler's total power consumption ranges from 150 W (per fan, low speed) to 300 W (per fan, full speed) for a 50 kW module. With variable - speed control, the average power use is reduced by 30% compared to fixed - speed coolers, translating to annual energy savings of $2,000–$5,000 per module (based on 0.15 $/kWh).
◆ Water - Free Cooling: By using ambient air for heat rejection, the cooler eliminates the need for water - based systems. This reduces water consumption by 100% for cooling, aligning with data centers' sustainability goals and reducing operational costs (no water treatment or plumbing maintenance).

 

5

Application & Compatibility

◆ Retrofit Scenarios: Ideal for upgrading legacy data centers. The modular design fits into existing rack layouts, and the compact size (800mm × 1200mm × 1500mm per module) works in repurposed industrial buildings or purpose - built facilities.

◆ Compatibility: Integrates with common data center infrastructure (e.g., Liebert, Delta cooling systems). It supports both direct and indirect air - cooling architectures, providing flexibility for different server layouts.

 

6

Logistics & Delivery

◆ Packaging: Modules are shipped in wooden crates (1200mm × 1000mm × 1800mm) with anti - vibration padding, ensuring safe transit.
◆ Delivery Time: Standard lead time is 4–6 weeks for custom orders. In - stock modules (50 kW – 200 kW) ship within 1 week.
◆ Installation: On - site installation takes 1–2 days per module (including wiring and integration), with support from the manufacturer's technical team.

Hot Tags: horizontal dry cooler, China horizontal dry cooler manufacturers, suppliers, factory, Computing Center Dry Cooler, Data Center Dry Cooler, dry cooler, Glycol Dry Cooler, Horizontal Dry Cooler, Injection Mold Cooling Dry Cooler